Test EQ

IEC 60068-2-39: Low Air Pressure Combined Environmental Testing
Release time:  2025-06-02 10:19:09

IEC 60068-2-39:2015 defines test methods and guidance for evaluating equipment and components under combined temperature or temperature and humidity with low air pressure conditions.

The standard is used to investigate how electrical, electronic, mechanical, and other equipment respond when reduced atmospheric pressure is combined with thermal or humidity stress.

For engineers selecting a test chamber, the key requirement is not simply altitude simulation. The chamber must provide controlled and repeatable low air pressure, temperature, humidity when required, exposure time, and recovery conditions.


What Is IEC 60068-2-39?

IEC 60068-2-39 is part of the IEC 60068 environmental testing series.

The 2015 edition is titled:

Environmental testing – Part 2-39: Tests – Tests and guidance: Combined temperature or temperature and humidity with low air pressure tests.

The purpose of the test is to determine whether equipment or components experience electrical, mechanical, physical, or functional changes when exposed to combined environmental stresses.

Unlike a basic altitude test that primarily simulates reduced atmospheric pressure, IEC 60068-2-39 addresses the interaction between low air pressure and temperature or temperature/humidity conditions.

Typical applications include aerospace electronics, avionics, defense equipment, electronic assemblies, automotive electronics, communication equipment, and other products intended for low-pressure operating environments.


IEC 60068-2-39 Test Z/AMD

IEC 60068-2-39:2015 is associated with the updated Test Z/AMD approach for combined environmental testing.

The standard provides preferred combinations of temperature, low air pressure, humidity where applicable, and exposure duration. The actual test severity should be selected according to the applicable IEC 60068 series requirements and the product specification.

This distinction is important when defining a chamber specification:

IEC 60068-2-39 is a combined environmental test method, not simply an altitude-equivalent pressure test.

The chamber and test profile should therefore be specified according to the required temperature, pressure, humidity, specimen operating state, exposure duration, and recovery conditions.


What Does IEC 60068-2-39 Test?

IEC 60068-2-39 evaluates equipment under combinations of:

• Temperature

• Low air pressure

• Temperature and humidity

• Exposure duration

• Operating or non-operating conditions

• Recovery conditions

The objective is to identify environmental effects that may not appear when temperature, humidity, or pressure are evaluated independently.

Potential failure mechanisms may include:

• Electrical insulation degradation

• Seal or enclosure leakage

• Mechanical deformation

• Material property changes

• Electronic malfunction

• Changes in electrical performance

• Functional instability under reduced pressure

• Failure after combined environmental exposure

The exact test severity should always be defined by the applicable product specification or relevant IEC 60068 test requirement.


IEC 60068-2-39 Test Conditions

The standard provides preferred combinations of temperature, low air pressure, and exposure duration.

Depending on the applicable test sequence, the environmental condition may involve:

Temperature + Low Air Pressure

The specimen is stabilized at the specified temperature before the chamber pressure is reduced to the required low-pressure condition.

Temperature + Humidity + Low Air Pressure

Where humidity exposure is required, the test combines controlled temperature and humidity conditions with reduced air pressure.

The selected condition depends on the product, intended operating environment, and applicable specification.


IEC 60068-2-39 Test Requirements

IEC 60068-2-39 testing requires products to be evaluated under combined environmental stresses where reduced air pressure is applied together with temperature and humidity conditions. The purpose of this test is to determine whether equipment can maintain its performance and reliability when exposed to high-altitude environments or low-pressure operating conditions.

Compared with standard altitude testing that mainly focuses on pressure reduction, IEC 60068-2-39 emphasizes the combined effects of multiple environmental factors. The test conditions are selected according to the product application, operating environment, and required reliability level.


Key Test Parameters of IEC 60068-2-39

Test ParameterDescription
Low Air PressureSimulates reduced atmospheric pressure conditions experienced at high altitudes
Temperature ConditionApplies cold or high-temperature environments combined with low pressure
Humidity ConditionEvaluates product performance under moisture-related stress when required
Pressure ControlRequires stable and accurate adjustment of chamber pressure
Exposure DurationMaintains specified environmental conditions for a defined testing period
Recovery ConditionAllows the specimen to return to normal atmospheric conditions before evaluation


Key IEC 60068-2-39 Chamber Requirements

A chamber used for IEC 60068-2-39 testing should be evaluated according to the complete test profile rather than temperature range alone.

Engineering RequirementWhy It Matters
Low Air Pressure ControlReproduces the required reduced atmospheric pressure conditions.
Pressure StabilityMaintains stable and repeatable test conditions throughout the exposure period.
Controlled Pressure RampPrevents uncontrolled pressure transitions and supports repeatable testing.
Temperature ControlProvides the required thermal stress for the specified test condition.
Temperature UniformityEnsures consistent temperature exposure across the test specimen.
Humidity ControlSupports applicable test sequences that combine temperature, humidity, and low air pressure.
Programmable Test ProfilesEnables automated multi-stage temperature, pressure, and humidity sequences.
Pressure & Temperature MonitoringProvides real-time monitoring and improves test traceability.
Data RecordingRecords critical test parameters for qualification, verification, and reporting.
Specimen Operating CapabilityAllows the DUT to remain operational when functional testing is required.
Recovery ControlSupports controlled pressure and temperature recovery for consistent post-test evaluation.

For procurement, engineers should define the chamber from the required test sequence instead of selecting equipment only from a nominal altitude rating.


What Pressure Range Is Required?

IEC 60068-2-39 does not mean that every application requires the same fixed pressure level.

The required low-air-pressure condition should be selected from the applicable test severity and product specification.

Therefore, a chamber specification should define:

• Required minimum pressure

• Normal atmospheric pressure

• Pressure control accuracy

• Pressure change rate

• Pressure recovery rate

• Required exposure duration

• Required temperature range

• Humidity range when applicable

• Specimen volume and load

• Operating condition of the specimen

This approach avoids selecting a chamber based only on an advertised altitude number.


Products Commonly Tested According to IEC 60068-2-39

IEC 60068-2-39 testing is commonly applied to products that may operate in high-altitude or low-pressure environments, including:

  • Aerospace electronic equipment

  • Avionics systems

  • Military electronic components

  • Automotive electronic modules

  • Communication equipment

  • Semiconductor devices

  • Industrial control systems

These products require verification to ensure reliable operation when exposed to combined environmental stresses.


IEC 60068-2-39 Test Procedure

IEC 60068-2-39 testing follows a controlled environmental simulation process to evaluate product performance under combined low air pressure, temperature, and humidity conditions. The typical test procedure includes the following six steps:

1. Specimen Preparation

Install the specimen according to the applicable product specification.

The specimen may be tested unpacked and either operating or non-operating depending on the required test condition.

2. Temperature Stabilization

The chamber is adjusted to the specified temperature.

The specimen is allowed to reach temperature stability before the low-pressure stage begins.

IEC 60068-2-39 specifies that the temperature change rate should not exceed 1 K/min during the applicable test sequence.

3. Low Air Pressure Reduction

After temperature stabilization, chamber pressure is reduced to the specified low-air-pressure condition.

The pressure change rate should not exceed 15 kPa/min for the applicable procedure.

Stable pressure control is important because uncontrolled pressure changes can affect test repeatability and specimen response.

4. Combined Environmental Exposure

The required temperature and low-pressure conditions are maintained for the specified exposure duration.

Where applicable, humidity is also controlled according to the selected test condition.

The exposure period is measured from the required temperature stability condition under low air pressure.

5. Functional or Intermediate Measurements

For electrically operated specimens, functional checks and intermediate measurements may be performed according to the relevant product specification.

Typical monitored parameters may include:

• Chamber pressure

• Temperature

• Humidity where applicable

• Specimen operating status

• Electrical parameters

• Functional performance

6. Pressure Recovery

After the required exposure period, chamber pressure is restored toward normal atmospheric pressure.

The pressure recovery rate should remain within the applicable standard requirement.

7. Temperature Recovery and Final Evaluation

The specimen remains in the chamber until the required recovery condition is achieved.

Final electrical, mechanical, dimensional, or functional measurements can then be compared with the initial condition.


IEC 60068-2-39 vs Altitude Test Chamber

Altitude testing and IEC 60068-2-39 are related but should not be treated as identical.

ItemAltitude TestingIEC 60068-2-39
Primary PurposeSimulate reduced atmospheric pressure and altitude conditionsEvaluate equipment under combined environmental conditions
Low PressureYesYes
TemperatureMay be combined depending on the test requirementCore test parameter
HumidityDepends on the test requirementIncluded where applicable
Main FocusAltitude and reduced-pressure environmentTemperature or temperature/humidity combined with low air pressure
Typical ApplicationsAerospace, aviation, electronicsAerospace, electronics, defense, industrial equipment
Typical EquipmentAltitude Test ChamberCombined Low-Pressure Environmental Chamber

For a product that only requires low-pressure or altitude simulation, an altitude test chamber may be appropriate.

For a qualification program involving temperature or temperature/humidity together with low air pressure, the chamber should be specified for the complete IEC 60068-2-39 test sequence.


IEC 60068-2-39 vs IEC 60068-2-40 and IEC 60068-2-41

These standards belong to the same family of combined environmental testing methods but address different combinations.

IEC 60068-2-39

Focuses on:

Temperature or temperature + humidity with low air pressure

IEC 60068-2-40

Addresses:

Low temperature + low air pressure

IEC 60068-2-41

Addresses:

Dry heat + low air pressure

The correct standard should therefore be selected according to the environmental stress that the product specification requires.

For multi-standard qualification programs, the chamber should be configured to support the complete required test matrix.


How to Select an IEC 60068-2-39 Test Chamber

For B2B procurement, the following parameters should be confirmed before requesting a quotation.

1. Required Pressure Range

Specify the minimum pressure and normal atmospheric pressure required for the test.

2. Temperature Range

Define the required cold and/or dry-heat conditions.

3. Humidity Requirement

If the qualification program includes humidity, specify the required humidity range and temperature/humidity operating envelope.

4. Chamber Working Volume

Select the internal working volume based on:

• DUT dimensions

• Fixture dimensions

• Number of specimens

• Required airflow

• Heat load

• Maintenance access

5. Pressure Control and Ramp Rate

Ask the supplier to specify pressure control accuracy, stability, reduction rate, and recovery rate.

6. Temperature Uniformity

Temperature uniformity should be evaluated under the actual chamber loading condition rather than under an empty chamber.

7. Data Acquisition

For qualification testing, pressure, temperature, humidity, alarms, test time, and specimen status should be recorded for traceability.

8. Custom Integration

Large aerospace or industrial specimens may require custom chamber dimensions, electrical feedthroughs, observation windows, cable ports, specimen fixtures, or integrated monitoring systems.


TestEQ Solution for IEC 60068-2-39 and Altitude Testing

TestEQ hypobaric altitude chambers are designed to support advanced environmental simulation requirements, including:

  • Low air pressure simulation

  • Temperature control

  • Humidity testing capability

  • Combined environmental stress testing

These systems help engineers perform reliable validation for aerospace, defense, automotive electronics, semiconductor, and other high-reliability applications.


TestEQ IEC 60068-2-39 Low Air Pressure Test Chamber

TestEQ provides customized environmental test systems for applications requiring controlled low air pressure combined with temperature and humidity conditions.

The system can be configured for:

  • Low air pressure simulation

  • Temperature control

  • Humidity control where required

  • Programmable pressure profiles

  • Temperature and pressure monitoring

  • Combined environmental testing

  • Data acquisition and test recording

  • Custom specimen fixtures

  • Custom chamber dimensions

A typical TestEQ configuration supports a pressure adjustment range of approximately 5 kPa to 100 kPa, with the final specification determined by the required test profile and chamber configuration.

The system can be engineered for applications including aerospace electronics, avionics, defense equipment, automotive electronics, semiconductor components, communication equipment, and laboratory reliability testing.


Why Choose TestEQ for IEC 60068-2-39 Low Air Pressure Testing?

1. Combined Environmental Simulation

TestEQ designs environmental test systems around the complete test condition rather than pressure simulation alone.

2. Engineering-Based Chamber Configuration

Chamber size, temperature range, pressure range, humidity capability, specimen loading, and monitoring can be configured according to the customer's qualification requirements.

3. Multi-Standard Testing

The same environmental testing platform can be configured to support applicable IEC 60068, MIL-STD, RTCA DO-160, and other qualification requirements where the chamber specification permits.

4. Pressure and Temperature Control

Controlled pressure reduction, temperature regulation, monitoring, and recovery help engineers achieve repeatable environmental conditions.

5. Custom Test Systems

TestEQ can provide customized chamber dimensions, fixtures, electrical interfaces, monitoring systems, and test-control configurations for specialized applications.

6. Reliability Testing Applications

TestEQ environmental testing systems are used for demanding applications in aerospace, automotive electronics, semiconductor, defense, and industrial research.

7. Engineering Support

TestEQ supports the chamber selection process from test-condition definition and system configuration through installation and technical support.


IEC 60068-2-39 Applications

Aerospace and Avionics

Evaluate avionics, aircraft electronics, sensors, communication equipment, and other airborne systems under reduced pressure and thermal conditions.

Defense Electronics

Verify equipment performance under combined environmental conditions specified by military or product qualification programs.

Automotive Electronics

Evaluate electronic controllers, sensors, communication modules, and other components where altitude and temperature conditions may affect reliability.

Semiconductor and Electronic Components

Investigate functional stability and environmental response of electronic assemblies and components under controlled low-pressure and temperature conditions.

Industrial Equipment

Test measurement instruments, control systems, and specialized equipment intended for operation in reduced-pressure environments.


Frequently Asked Questions About IEC 60068-2-39 Low Air Pressure Testing

1.What is IEC 60068-2-39?

IEC 60068-2-39:2015 is an environmental testing standard for evaluating equipment and components under combined temperature or temperature and humidity with low air pressure conditions.


2.Is IEC 60068-2-39 an altitude test?

It can be used to reproduce reduced-pressure conditions associated with altitude, but the standard is broader than a basic altitude simulation test because it addresses combined temperature or temperature/humidity with low air pressure.


3.What is Test Z/AMD?

Test Z/AMD refers to the combined environmental testing approach associated with IEC 60068-2-39. The applicable temperature, low-pressure, humidity, and exposure conditions should be selected according to the relevant specification.


4.Does IEC 60068-2-39 require humidity?

Not every test condition requires humidity. IEC 60068-2-39 covers temperature with low air pressure and temperature/humidity with low air pressure. The applicable sequence depends on the product specification.


5.What chamber is used for IEC 60068-2-39?

A low-pressure environmental chamber, hypobaric chamber, or altitude simulation chamber can be configured for IEC 60068-2-39 when it provides the required pressure, temperature, humidity, monitoring, and test-sequence capabilities.


6.What pressure should an IEC 60068-2-39 chamber reach?

There is no single pressure value applicable to every IEC 60068-2-39 application. The required pressure should be selected from the applicable test severity and product specification.


7.What is the pressure change rate in IEC 60068-2-39?

For the applicable test procedure, the pressure change rate should not exceed 15 kPa/min. The complete test specification should be reviewed before configuring the chamber.


8.What is the temperature change rate?

For the applicable test sequence, the temperature change rate should not exceed 1 K/min. The actual test profile should be established from the applicable standard requirements and product specification.


9.Can TestEQ customize an IEC 60068-2-39 chamber?

Yes. TestEQ can configure low-pressure environmental testing systems according to required pressure, temperature, humidity, chamber volume, specimen fixtures, monitoring, data acquisition, and other engineering requirements.


Internal Linking Module

Recommended Equipment

Related Test Equipment for IEC 60068-2-39 Low Pressure Testing

1. Altitude Test Chamber

Simulates high-altitude and low-pressure environments for aerospace, defense, electronics, and reliability testing applications.

2. Temperature Humidity Chamber

Provides precise temperature and humidity control for environmental reliability tests based on IEC 60068 and other international standards.

3. Thermal Cycling Chamber

Designed for repeated temperature cycling tests to evaluate product reliability under changing environmental conditions.


Related Standards

Related Environmental Testing Standards

1. IEC 60068 Environmental Testing Standard

Provides an overview of IEC 60068 environmental testing methods, including temperature, humidity, vibration, and combined environmental tests.

2. MIL-STD-810H Environmental Testing Standard

Explains military environmental testing requirements for equipment exposed to extreme temperature, altitude, humidity, vibration, and shock conditions.

3. RTCA DO-160 Environmental Testing Standard

Covers environmental qualification testing requirements for airborne equipment and avionics systems.


Technical Resources

Related Guides for Low Pressure and Environmental Testing

1. What Is Altitude Testing? Complete Guide for Reliability Testing

Explains altitude simulation testing methods, applications, and how low-pressure environments affect product reliability.

2. How to Choose an Environmental Test Chamber

Provides guidance on selecting environmental test chambers based on temperature range, humidity control, testing standards, and applications.

3. MIL-STD-810H Altitude Test Method Guide

Introduces MIL-STD-810H altitude testing procedures and explains the differences between military and commercial environmental testing requirements.


CTA

Need an IEC 60068-2-39 Test Chamber?

If your qualification program requires low air pressure combined with temperature or temperature and humidity, TestEQ can help configure an environmental test chamber around the required test sequence.

Provide your required:

• Pressure range

• Temperature range

• Humidity range

• Chamber working volume

• Specimen dimensions

• Test duration

• Applicable standards

• Required monitoring and data acquisition

Contact TestEQ engineers for an IEC 60068-2-39 chamber configuration and technical quotation.


"Request a Technical Consultation →" 

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with
the suffix "@test-eq.com".

We will contact you within 1 working day, please pay attention to the email with the suffix "@test-eq.com".

Company
Name*
Phone
E-Mail*
Nation
Message
By selecting the ‘I agree’ button, you consent to the processing of your personal data for marketing purposes and for the sending of commercial information by TESTEQ Company through telephone, e-mail, newsletters, text messages such as sms, chat and social networks.
I AGREE
By submitting your personal data, you declare that you have read the Privacy Policy of the website.

P.IVA: 91441900MAECQJHY37 Guangdong Test EQ Equipment Co., Ltd. | All Rights Reserved